Industry

What are the common faults of the traveling motor of the walkie stacker?

0

Published by NEWTON October 25,2024

As the name implies, walkie stacker is a storage and logistics vehicle driven by electricity. We can see it in supermarkets, factories, docks, airports and other places. Therefore, the electrical system is very important for the walkie stacker. Once it fails, the walkie stacker may no longer work normally, and may even cause accidents. So, what faults are prone to occur in the electrical system? What is the cause of this failure? Today, the pallet stacker manufacturer will tell you about the common faults and causes of the walking motor, the core component of the electrical system.

walkie stacker

The first common fault of the traveling motor of the walkie stacker is that it cannot start normally. The causes of this problem may be as follows: the fuse is burnt; Different control lines; The coil of the motor has serious short circuit or open circuit; Short-circuit between commutators; Poor contact of carbon brush; Excessive load or mechanical damage of bearings. The pallet stacker manufacturer told everyone that the second common fault of the traveling motor is the abnormal speed. This problem may be caused by the following reasons: short circuit or open circuit of the motor coil; The brush position is incorrect and overloaded; Bearing damage; The supply voltage is too low.

The third common fault of the traveling motor of the walkie stacker is the spark of the brush. The causes of this problem may be as follows: poor contact of carbon brush; The commutator surface is uneven; The carbon brush position is not correct; The surface of carbon brush is not clean; Short circuit of commutation plate; It is caused by short circuit of motor coil. The fourth common problem of the traveling motor is that the temperature is too high. The causes of this problem may be as follows: overload; The bearing and oil seal are too tight, damaged or poorly lubricated; Axis misalignment; Friction between armature and stimulation; Coil short circuit; The brush pressure is too high and the position is not correct; Poor rectification. The fifth common problem of traveling motor is noise. The pallet stacker manufacturer told us that the causes of this problem are as follows: bearing damage; The commutator surface is uneven; The carbon brush vibrates or rubs.

walkie stacker

These are the five common problems and causes of the traveling motor of the walkie stacker. If there is a problem with the traveling motor of the walkie stacker, the driver should not worry, and just check according to the reasons stated by the pallet stacker manufacturer. If you still can't find the problem, it is recommended to ask for professional maintenance personnel. Customers can also consult the after-sales service personnel of the pallet stacker manufacturer. We will solve the problem online 24 hours a day.

< >

 

Technical Support: Magic Lamp